Particulate Matter Sensor PMS5003 with Cable

13-00012933
COM1707
ΚατασκευαστήςOem Part NumberCOM1707
Διαθέσιμο
Αποστολή σε 24 ώρες
3290
Gropbotronics Store Availability
Διαθεσιμότητα Καταστημάτων
Πληρωμή & Μεταφορικά

Monitor air pollution cheaply and accurately with this matchbox-sized particulate matter (PM) sensor from Plantower! It senses particulates of various sizes (PM1, PM2.5, PM10) from sources like smoke, dust, pollen, metal and organic particles, and more.

Plantower PMS5003 is a laser dust sensor. Sensor uses laser light scattering principle to measure value of dust particles suspended in the air. Sensor provides precise and reliable reading of PM2.5 value.

Pair this particulate matter sensor with our Enviro plus and build your own air quality monitoring station to contribute to citizen science. Just plug the cable into the sensor and then into the connector on the underside of Enviro plus, and away you go!

The sensor has a small fan that sucks air through the sensor and past a laser that can detect both the number (and hence concentration) and size of particles in the surrounding air.

 

ΣΗΜΕΙΩΣΕΙΣ

  • There's a blue protective film that covers the metal casing of the sensor, and you can peel this off before use.

Software

Our Python library for the PMS5003 sensor lets you read PM1, PM2.5, and PM10 in both standard and environmental units, and numbers of particles of various sizes: >0.3, >0.5, >1.0, >2.5, >5, and >10um.

Note that if you're using this sensor with Raspberry Pi, then you'll need to make a couple of changes to its configuration. Type sudo raspi-config in the terminal and then under "Interfacing options" and "Serial" disable the login shell and enable the serial port hardware. Edit your /boot/config.txt file and add the lines enable_uart=1 and dtoverlay=pi3-miniuart-bt to the bottom of the file.

Our Enviro plus installation script will do all of this configuration for you.

  • Supply voltage: from 4.5 V to 5.5 V
  • Power consumption (work): below 100 mA
  • Power consumption (standby): below 200 μA
  • Sensitivity:
    • 50% - 0.3 μm
    • 98% - 0.5 μm and larger
  • Resolution: 1 μg/m³
  • Work temperature: od -10 °C do 60 °C
  • Humidity (work): 0-99%
  • Dimensions: 50x38x21mm

Pinout:

Pin 1 from inside. Pin 8 on the outside. 8-pin connector (1.25mm raster).

Pin Function Description Remarks
1 VCC Supply voltage 5V 4.5 - 5.5V
2 GND Ground  
3 SET HIGH or SUSPENDED - work mode
LOW - sleep mode
3.3V logic
4 RXD UART/TTL data recieve 3.3V logic
5 TXD UART/TTL data transmit 3.3V logic
6 Reset LOW to reset 3.3V logic
7 NC Not connected  
8 NC Not connected  
  • Plantower PMS5003 Particulate Matter (PM) Sensor
  • Detects PM1, PM2.5, PM10 particulates
  • 15cm Picoblade cable
  • UART serial interface
Κατασκευαστής
Oem
Part Number
COM1707
Εγγύηση
Ως εξάρτημα, δεν καλύπτεται
Καθ. Βάρος
0.045kg
Τύπος Αισθητήρα
  • Σκόνης
Τυπική Τάση Εισόδου
  • 4.5VDC
  • 5VDC
  • 5.5VDC
Ρεύμα Λειτουργίας
100mA
Διασύνδεση
  • Ψηφιακή
Πρωτόκολλο Eπικοινωνίας
  • UART
  • TTL Serial
Βρες Παρόμοια